DT10 Application

DT10 Application Download
Version 12.1.0 [English] Download 72.2 MByte 2017-10-18

Sentinel HL Dongle Run-time

DT10 Application Download
Version 7.60 Download 18.2 MByte 2017-07-19

The installation procedure is described in this page.

Revision history

Major Changes (Ver.11.3.0 ⇒ Ver.12.1.0)
  • [New] Supported the setting window for “Dynamic Tracer Storage”(*)
  • [New] Added the functionality of auto deletion of the older Report Data when Report collecting.
  • [New] Added the functionality to import the settings of conditional inclusion analysis from an external text file.
  • [New] DTConverter is converted to DTCmd.
  • [New] Supported the export of Process Occupational Ratio Scope.
  • [New] Added the Function Coverage Report.
  • [New] Added pulg-in menu to DT10 application.
  • [Functionality improvement] Supported lambda expression of C# for Test Point insertion.
  • [Functionality improvement] Supported the display ofthe number with a decimal point for current value when current measuring.
  • [Functionality improvement] Supported up to 64 cores of a target for Data Writing connection.
  • [Functionality improvement] Improved the functionality of Test Point insertion of DTCmd.
  • [Functionality improvement] improvement] Changed the display order of the analysis reports to the descending order.
  • [Functionality improvement] Supported the selecting of minimum time interval for CPU load rate.
  • [Functionality improvement] Supported the new project of subtool(DTDiff).
  • [Functionality improvement] Excluded the Hardware manual from the help menu.
  • [Bug fixed] Fixed the known issues.
  • * ”Dynamic Tracer Storage” is a hardware option that has SD card slot and that can save the trace result in SD card directly without using a PC.

Major Changes (Ver.11.1.0 ⇒ Ver.11.3.0)
  • [New] Added source code formatting function for branch coverage. (C/C++/Java)
  • [New] Added application filter function for Ethernet connection.
  • [New] Supported to display input data from AnalogBox as the current value.
  • [Functionality improvement] ”Variable Value Point” can be set as Trigger Test Point for starting or stopping Report acquisition.
  • [Functionality improvement] New Application updated for Windows 10.
  • [Bug fixed] Fixed the known issues.
Major Changes (Ver.11.0.1 ⇒ Ver.11.1.0)
  • [Functionality improvement] Added the help for AutomotiveEdition. (For AutomotiveEdition only)
  • [Functionality improvement] Improved the calculation method of Statement/Branch Coverage. (comply with ISO26262) (For AutomotiveEdition only)
  • [Functionality improvement] Improved the calculation method of Coverage to include “OFF” Test Points. (For AutomotiveEdition only)
  • [Bug fixed] Fixed the known issues.
Major Changes (Ver.11.00 ⇒ Ver.11.00.01)
  • [Bug fixed] Fixed the known issues.
Major Changes (Ver.10.51 ⇒ Ver.11.00)
  • [New] Improved the CAN connection
    ・By the new dynamic filter, the output target of the Test Points can be specified without recompilation.
    ・Supported the VN16XX series of Vector Japan Co., Ltd.
  • [New] Support for the GPIO-NoiseIsolator.
     Data receive is enabled by the isolation circuit under the noisy condition.
     And, flat cable can be connected to GPIO-NoiseIsolator so probes are more easily connected.
  • [New] Support for the I2C connection.
     Data receive is enabled by the 2 lines of generic port.
  • [New] New edition “Automotive Edition” is available.
     ”Automotive Edition” is newly released includes the functionality to measure the function-call coverage.
  • [Functionality improvement] Support for the “Fast Test Point Conversion” to multiple files.
  • [Functionality improvement] Support for the initialization of the windows position.
  • [Functionality improvement] Extend the identifiable function name in the application to 256 bytes.
  • [Functionality improvement] Change the definition of the KernelInfo Test Point macro.
     Variable-length parameter enables more flexible implement.
  • [Functionality improvement] Usability improvement for “Function Transition Scope”
    ・Change the motion by the mouse wheel ( Zoom in or out the view by the mouse wheel, and scroll the view by the mouse wheel and Ctrl key ).
    ・The marker line is modified to the translucence.
  • [Functionality improvement] HTML help is included instead of the User’s manual.
  • [Bug fixed] Fixed the known issues.
Major Changes (Ver.10.50 ⇒ Ver.10.51)
  • [Bug fixed] Fixed the known issues.
Major Changes (Ver.10.42 ⇒ Ver.10.50)
  • [Functionality improvement] New Application and DynamicTracer Driver updated for Windows 8/8.1
  • [Functionality improvement] Upgrade of the branch coverage analysis function
    ・Extension of profile automatic inheritance function of coverage information
    ・Addition of branch coverage detail list for multiple test reports analysis
  • [Functionality improvement] Support of constructor and destructor as function name
  • [Bug fixed] Fixed the known issues.
Major Changes (Ver.10.40 ⇒ Ver.10.42)
  • [Functionality improvement] Extended the functionality to specify the Test Point attribute at selected position.
     In addition of “Above”, “Below” and “Both”, “Block” can be selected in the functionality to search the Test Point position.
  • [Bug fixed] Fixed the known issues.
Major Changes (Ver.10.30 ⇒ Ver.10.40)
  • [Functionality improvement] Improved the Function Transition Scope.
     Added the functionality to hide the processes or threads which have no executed function on the Test Report when KernelInfo output point is used.
  • [Functionality improvement] The functionality of Test Point auto insertion into the only specified function in was added in DT command Line.
  • [Functionality improvement] Added the option to continue the auto insertion even if “#error” is detected when conditional inclusion analysis.
  • [Bug fixed] Fixed the known issues.
Major Changes (Ver.10.20 ⇒ Ver.10.30)
  • [New] Profile automatic inheritance for coverage information is now supported.
     More efficient test is now available because coverage information of the previous profile’s can be inherited automatically when the new profile is created.
  • [New] Test Point execution attribute specifying at selected position is now supported.
     Test Point execution attribute can be automatically set for a Test Point at the above or below line of specified identifier when the auto insertion.
  • [New] Import of Visual Studio project is now supported.
     Easier setting of “Conditional inclusion analysis” and easier registration of source files by the import of Visual Studio project.
  • [Functionality improvement] Insertion position of “#include” statement of DT header file has improved.
     Result of conditional inclusion analysis has been considered since this version and the statement is inserted in the valid area.
  • [Bug fixed] Fixed the known issues.
Major Changes (Ver.10.13 ⇒ Ver.10.20)
  • [Functionality improvement] Improvement for KernelInfo data display of the Function Transition Scope.
  •  Clear the transition of processes and threads and easier to figure out the kernel behavior.

  • [Functionality improvement] The name “PID” is changed to “TID” and “TGID” is changed to “PID” in the application when “kernelInfo” is used.
  • [Functionality improvement] Auto insertion and creating a new project are usable from command line.
  •  The automation for the operations of Dynamic Test Tool are available by using CI tools.

  • [Functionality improvement] Improvement of the display of data acquisition date and time
     The value after the decimal point can be displayed in “Elapsed time” column in a Test Report.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.10.11 ⇒ Ver.10.13)
  • [Functionality improvement]Added the registering function of the default setting for the Project setting.
    You can register the content of the Project setting as default setting since this version.
    And, You can also switch to the various of the settings by saving a backup of them because they are saved in an external file.
  • [Functionality improvement]Added “Viewer Mode”.
    “Viewer Mode” enables the analysis more smooth because you can analyze the Report data without registered source files in DT10 application when you open the project.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.10.10 ⇒ Ver.10.11)
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.10.01 ⇒ Ver.10.10)
  • [Functionality improvement] Upgrade Function Transition Scope
    Specified area analysis was added, and you can use a mouse wheel and show/hide the connecting line of the sequences (For Standard Edition only).
  • [Functionality improvement] When using “Data Writing”, if time data is 8 bytes, you can select the both of “absolute time” and “relative time” (For Standard Edition only).
  • [Functionality improvement] The name “Event Information Acquisition Format” was changed.
  • [Functionality improvement] Added the sorting function in “Variable selection” dialog.
  • [Functionality improvement] Added the analysis and export function of Execution Time Report(Flat mode) in DT Command Line (For Standard Edition only).
  • [Functionality improvement] Added the code page selecting function in the character code settings.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.10.00 ⇒ Ver.10.01)
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.9.31 ⇒ Ver.10.00)
  • [New] Add “Decision Coverage-specialized” mode in Coverage-specialized auto insertion.
  •     This mode enables you to get decision coverage correctly by modifying source code when the auto insertion.
        This is appropriate function for coverage measurement use.

  • [New] Support the EventTrigger to get the event value up to 32 bit.
  •     You can confirm the behavior of processes or OS (like Linux) by new EventTrigger.

  • [Functionality improvement] New “Process Mode” enables you to confirm the transition of core and process in Function Transition Scope.(*Standard Edition only)
  • [Functionality improvement] You can use absolute time in the report convertion of “Data Writing”.(*Standard Edition only)
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.9.30 ⇒ Ver.9.31)
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.9.13 ⇒ Ver.9.30)
  • [New] Conditional inclusion analysis is now also for C#.
  • [Functionality improvement] “enum” class is now supported in automatic insertion for Java source code.
  • [Functionality improvement] Static initializer and instance initializer is now supported in automatic insertion for Java source code.
  • [Functionality improvement] We have changed the phrase in Period Time Report as follows.”Pass count” -> “Period count”
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.9.12 ⇒ Ver.9.13)
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.9.11 ⇒ Ver.9.12)
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.9.11 ⇒ Ver.9.12)
  • [Functionality Improvement] You can enter “[]“(element of an array) in variable name to insert Variable Test Points into specified position.
Major changes (Ver.9.10 ⇒ Ver.9.11)
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.9.01 ⇒ Ver.9.10)
  • [New] Coverage-specialized auto insertion is added.
  •     Statement Coverage is now available by suitable Test Point insertion modifies source code aggressively.
        This feature is recommended for the users make much of coverage measurement.

  • [New] You can insert Variable Value Point into specified position.
  •     DT10 is now able to insert Variable Value Point automatically into the next line of specified strings.

  • [New] “Import/Export of Test Points ON/OFF status” is added.
  •     You can keep “ON/OFF” status for each Test Points and also backup.

  • [New] The subtool “DTConverter” gets a part of DT10, and report data import is now available.
  • [Functionality Improvement] You can modify filter setting also from Function Transition Scope.
  • [Functionality Improvement] The maximum resolution of Process Occupation Ratio Scope gets to 1000ms.
  • [Functionality Improvement] You can display folder column in Test Report.
  • [Functionality Improvement] You can see “Base adress” and “Data value” on DTPlanner.
  • [Functionality Improvement] You can select some items on Folder view and Module view using Shift key or Ctrl key.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.9.00 ⇒ Ver.9.01)
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.8.12 ⇒ Ver.9.00)
  • [New] Conditional compliation analysis feature is added. (Standard Edition only)
  •     It is now possible to insert Test Point only “TRUE” conditional code by specifying the include path or predifined macrons.

  • [New] Take over of the passed information feature is added.
  •     It is possible to take over the passed information of Test Point gathered with the previous pforile to the one of the current Test Report.
        You can refrect the previous test result to the C0 coverage rate, so this will lead to the efficient coverage test.

  • [Functionality Improvement] We have revamped the project settings dialog, the property editor interface.
  •     You can now to check the settings, which were complicated such as automatic insertion, in the list clearly by revamping the interface of project setting dialogue and property editor.

  • [Functionality Improvement] Improvement of process occupation ratio scope
  •     You can now sort of the list portion, highlight the line graph of the selected process, display by a broken line graph of the process at the time of check OFF.

  • [Functionality Improvement] Display base the value of the variable can now be specified individually.
  • [Functionality Improvement] Processing speed of the analysis report has been improved.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.8.11 ⇒ Ver.8.12)
  • [Others] The User’s manual (English), the Hardware manual (English) and the Installation Guide (English) were updated.
Major changes (Ver.8.10 ⇒ Ver.8.11)
  • [New] Support the Korean character set: “EUC-KR”.
  • [Functionality improvement] Improved the Command Line Execution feature.
        You can now display the souce code and display the functional transition scope.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.8.00 ⇒ Ver.8.10)
  • [New] Type specified Test Point Insertion Feature is added.
        When you perform the automatic Test Point insertion, you can now specified the type of Test Point (FuncIn、if …)
  • [New] “Function coverage” Check Feature is added.
        The “Executing Fucntion” field is added to the property view and DTPlanner in order to check the Function coverage.
  • [New] Command line execution feature is added.
        You can now operate DT10 from the command line.
  • [Functionality improvement] The syncronization feature of each window is enhanced.
        In the Window synchronization feature, Function Trace Report, Performance Monitor, Event Trace Report and Variable Monitor are now synchronized.
  • [Functionality improvement] The calcuration method of statement coverage was improved.
  • [Functionality improvement] Automatic Insertion process of C# is improved.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.7.30 ⇒ Ver.8.00)
  • [New] Function Transition Scope function was added.
        You can check with the graph which describes how each function was executed based on the displayed
        Test Report Data.
  • [New] The CAN connection was added to the connection methods.
  • [New] The import/export functions of column setting was added.
        Your can share the column settings of Test Report, Coverage Report, et al. by importing / exporting.
  • [New] The target time stamp append function was added.
        It is possible to append the time stamp generated by the target onto the obtained Report Data in GPIO,      SPI, SD connection.
  • [Functionality improvement] It is now possible to display the obtained date and time in the elapsed time field of the Test Report.
  • [Functionality improvement] The calcuration method of statement coverage was improved.
  • [Functionality improvement] The operation for filtering setting of the analisys report was unified.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.7.01 ⇒ Ver.7.02)
  • [Others] The Hardware manual (English) and the Installation Guide (English) were added.
Major changes (Ver.7.00 ⇒ Ver.7.01)
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.6.11 ⇒ Ver.7.00)
  • [New] The linkage function with the external tool: klocwork INSIGHT was added.
        The DT10 can execute the source code analysis function of the klockwork INSIGHT; it can detect
        and display the problems of a source code.
  • [New] The linkage function with the external tool:WatchPoint T was added.
        WATCHTPOINT can execute and stop the DT10′s test report collection function.
  • [New] The fast test point conversion function was added.
        The fast test point conversion which reduced the overhead in compared with normal test point.
        This enables you to confirm the target behavior which you face the difficulty when you use the
        normal test point due to the overhead.
  • [Functionality improvement] The report format of the variable output point report was changed.
        This enables you to reduce the overhead of the variable output since new format allows you to
        store maximum 8 byte of variables in one report data.
  • [Functionality improvement] The execution time collection function from the Ethernet connected target
        was added.
        This feature enables you to choose either generating the test report’s execution time information
        by DynamicTracer or generating by the target program in case of Ethernet connection.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.6.10 ⇒ Ver.6.11)
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.6.02 ⇒ Ver.6.10)
  • [Functionality improvement] The number of variables (Var) of the multi-wave scope was increased up to 10.
  • [Functionality improvement] The design of configuration setting dialog was changed.
  • [Functionality improvement] The new connection mode which can collect data without using Dynamic Tracer
        with Ethernet connection and UART connection was added. (Standard Edition only)
  • [New] The character code setting feature was added.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.6.01 ⇒ Ver.6.02)
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.6.00 ⇒ Ver.6.01)
  • [Functionality improvement] The performance of sort process of the time detail report was improved.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.5.20 ⇒ Ver.6.00)
  • [New] Real-time coverage function was added.
        You can check the Statement Coverage rate during generating test report.
        The function of the coverage report was also expanded.
        The function of displaying the Not Executed TP List and the function that the color coded of
        background changes depending on its coverage rate were added.
  • [New] Supported the multi-core CPU.
        The DT10 can now trace the movement of Max. 4 cores of the multi-core target.
        You can display the test report for each core and check the CPU load rate of each core by
        using the performance monitor.
  • [New] The DT10 application supports the 64bit OS system requirement.
  • [New] The DT10 adopted a floating license.
  • [New] The multi-edition structure was changed.
        The Entry edition was discontinued.
        In the Free edition, the restriction of maximum number of file was abolished and a restriction
        in the analysis menu was added.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.5.11 ⇒ Ver.5.20)
  • [New] The name of discard function duplicate report data was changed to “One-time trace report”.
  • [New] The two options were added to the one-time trace mode.
        ”Test report save option” (The function to save the previous report to another file at the time the
        specified test point was executed.)
        and “Restart option” (The function to restart the one-time trace at the time the specified test point
        was executed.)
  • [New] The specification of the specified analysis range was changed.
        It is possible to input a value greater than or equal to the end test report into the end value field when     you specified the range in “Report No.” and “Execution time”.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.5.10 ⇒ Ver.5.11)
  • [New] The test item name is now displayed in the window title field of the test report list.
  • [New] It is fixed the bug that the report data file switches to another file when the buffer becomes full.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.5.01 ⇒ Ver.5.10)
  • [New] The display function that you can specify the bit in the variables on the multi-wave scope was added.
        It is useful to check the transition of each bit when you define bit fields in variables.
  • [New] The discard function duplicate report data was added.
        When you generate the report, this function discard the executed report data. So when you generate
        the report for Statement Coverage measurement, it can reduce the amount of data.
  • [New] The upward search function of test report data from folder view and module view was added.
  • [Functionality improvement] The accuracy of difference acquisition data in the DTDiff was improved.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.5.00 ⇒ Ver.5.01)
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.4.11 ⇒ Ver.5.00)
  • [New] The DT10 now supports Java source code.
  • [New] The DT10 supports SD interface.
  • [New] The variable rewriting function was added.
        You can check the change of behavior by replacing the specified variable at the time of generating the test report.
        This enables you to evaluate the change of behavior without changing the target program.
  • [Functionality improvement] The analysis range of Function Trace Report was expanded to 2,097,152
        records in the volume data and 24 days (=2,073,600 seconds) in time scale.
  • [Functionality improvement] It is now possible to display the designated test report data only in the
        functional trace by filter setting.
  • [Functionality improvement] You can import or export the event definition.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.4.10 ⇒ Ver.4.11)
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.4.01 ⇒ Ver.4.10)
  • [New] The trimming function of Test Report was added. You can retrieve
        the part only where necessary and save as an another Test Report by trimming function.
  • [New] The function of performing real time Report Analysis was added.
        This function enables you to display Coverage Report, Execution Time Report and Period Time Report
        during generating a Test Report with executing report analysis.
  • [New] Loop Count Report was added.
  • [Functionality improvement] DTAdvisor function was enhanced.
        We enhanced the folder view, module view and dynamic module view function; function execution status
        function; step tracer function; preference dialog in DTAdvisor.
        We also add the Function Performance Table feature.
  • [Functionality improvement] We enhanced the property editor.
        We added the interface tab in the Function property and Step property.
        We also added the function to specify a variable in the variable property, Input-Output property,
        Range item.
  • [Functionality improvement] We enhanced the various reports.
        The bulk disabling of the executed test points function was added to the Coverage Report.
        The “Typ head” item was added to the Period Time Report.
        The task analysis mode by event trigger in the Function Trace was added.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.4.01 ⇒ Ver.4.02)
  • [new] The font change function of the source code window was added.
Major changes (Ver.4.00 ⇒ Ver.4.01)
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.3.21 ⇒ Ver.4.00)
  • [New] DTAdvisor function was added.
        The judgement function whether a program executed in normal path or a program executed in abnormal
        path by monitoring a function of parent-child relationship was added
  • [New] Branch Coverage function was added.
        The Branch Coverage which stands the coverage rate of the executed route in each branch was supported.
  • [New] The Combined Report function was added.
        The function that analyze the user specified report in the multiple Test Reports within the same
        profile and output the results in the Coverage Report, Execution Time Report, Period Time Report.
  • [New] The function enabling the filter setting and color-coding in the
        Test Report.
        The function enabling a specified field strings or values turning hide or color-coded was added.
        These functions allow you to customize the Test Report View easy-to-see.
  • [New] The search function in Test Report was added.
        The search function within a Test Report from Test Report View was added.
        You can search the items such as “source file name”, “function name”, “module name”.
  • [Functionality improvement] We enhanced DTMerger function.
        DTMerger maintains the integrity of Test Point information between DT project and the source code.
        With this modification, it is possible to rollback the previous property information of every Test
        Points against the latest source code without Test Points.
  • [Functionality improvement] We improved the tool bar.
        We picked up the frequently used functions and placed in the tool bar.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.3.10 ⇒ Ver.3.20)
  • [New] One installer made the installation of each edition possible.
Major changes (Ver.3.02 ⇒ Ver.3.10)
  • [New] The scaling setting function of the AnalogBox data was added.
        The function to display by the value that had been scaled was added
        though the data acquired in an AnalogBox displayed the value acquired in 8 bit resolution
        as it is in the test report and the multi wave scope.
  • [New] The insertion position specification functions of the include statement were added.
        The function of embedding Include sentence was added, to the following line of the line
        that specifies a specific character string, retrieves the character string, and is found first.
  • [New] DTDiff was added as a side tool.
        In DTDiff, two source files can be compared, and the part with the difference can be extracted,
        and the test point can be embedded under the code change point.
        In DTDiff, the operation of the change part can be easily confirmed by embedding
        the test point only under the change point.
  • [Functionality improvement] Operativeness in the Multi Wave Scope was strengthened.
  • [Functionality improvement] The operativeness of the property editor has been improved.
  • [Functionality improvement] The operativeness of the import function has been improved.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.2.50 ⇒ Ver.3.02)
  • [New] It corresponded to AnalogBOX.
        The measurement data can be added to past trace data by using AnalogBOX.
        The movement of software and hardware can be confirmed together by acquiring
        the measurement data by using AnalogBOX, and seeing with DT10.
  • [New] The check function of the test point automatic operation insertion cancel point was added.
        The insertion is canceled when there is a pre-processor in the insertion position of the
        test point when the test point is inserted automatically. The cancel position can be checked.
  • [Functionality improvement] Operativeness and the edit function of the source code Edith function were strengthened.
  • [Functionality improvement] The close button of the progress dialog was deleted.
  • [Functionality improvement] When the project changed, the title display was changed.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.2.40 ⇒ Ver.2.50)
  • [New] DT Marge was added.
    It is a function to detect by the automatic operation and to bury the insertion position of the test point again when there is a change in the source code registered in the file of the project of DT10 and the source code of the main body.
    It became possible to bury the same point before it changed to the edited source code easily.
  • [Functionality improvement] Operativeness and the edit function of the report Edith function were strengthened.
  • [Functionality improvement] The function that was able to jump to the point that measured the performance monitor was added.
    Moreover, after it had tested, it came to be able to confirm the result of CPU load measurement.
  • [Bug fixed] Fixed the known issues.
Major changes(Ver.2.31 ⇒ Ver.2.40)
  • [New] The report function of time of the cycle (The function time (maximum/minimum etc.) of the cycle was displayed and preserved) was added.
  • [New] The detailed list display was added to the execution time report and the report of time of the cycle.
    The display of “How much time in which part did it take?” is enabled in a detailed list.
  • [New] The profile function for creation (The profile is made by hand power) was added.
  • [Functionality improvement] The automatic extracting of the function trace report excluding the function entrance became possible.
  • [Functionality improvement] The display and operativeness of the event trace function were strengthened.
  • [Functionality improvement] Order sending/reverse order sending function of the test report display was added, and the improvement of operativeness was aimed at.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.2.30 ⇒ Ver.2.31)
  • [Functionality improvement] A disunited item of the description of the argument and the variable attribute was corrected.
  • [Functionality improvement] The drawing function of the test point insertion and the deletion position has been improved.
  • [Functionality improvement] An unnecessary function of the property editor (list mode) was deleted.
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.2.01 ⇒ Ver.2.30)
  • [New] EtherNet and UART were added to connected method.
  • [New] The automatic argument burial function was added.
  • [New] The event trace function was added.
  • [Functionality improvement] The filter setting preservation function was added.
  • [Functionality improvement] The fontsize change function of the source file view was added.
  • [Functionality improvement] The color changing function of the source file view was added.
  • [Functionality improvement] The analytical range number of function trace functions has been expanded. ( The maximum 65535→196608)
  • [Bug fixed] Fixed the known issues.
Major changes (Ver.1.20 ⇒ Ver.2.01)
  • [New] It corresponded to the C++ source code.
  • [New] The DTPlanner function (It is a function that the list list was able to be displayed as for the content of the property editor) was added.
  • [New] DTSimpleTracer (single function tool for the trace data acquisition) was added as a side tool.
  • [New] DTDriverWizard (driver automatic making tool) was added as a side tool.
  • [New] The CSV export function of the test report was added.
  • [Functionality improvement] It came to be able to do the import of property information from another project.
  • [Functionality improvement] It came to be able began/to end the trace by making a specific test point a trigger.
  • [Functionality improvement] It came to be able to specify the batch by the test point type effective/invalidity of the test point.
  • [Functionality improvement] The corresponding character-code was strengthened. (EUC-JP/UTF8/UTF16/various line feed codes etc.)
  • [Bug fixed] Fixed the known issues.